Skip to content

**REFURB** Bosch Solution 6000 PCB Only + CP737B White Graphic Colour WiFi Keypad With Integrated Smart Card Reader (Fob: PR301, ISO Card: PR350)

by Bosch
SKU **RF**CC610GWF-2

Notify me when back in stock

Bosch **Refurbished** Solution 6000 PCB Only + CP737B White Graphic Colour WiFi Keypad With Integrated Smart Card Reader

Please Note The Fault Has Been Fixed - Original fault: LAN Trouble Communication Fail, Panel Couldn't Be Brought Online Due To Keypad Fault - Supplier Replaced Keypad With New One - Box Seal Opened - 6 Months Warranty - SN: TBA

Bosch Solution 6000 PCB CC610P | F.01U.294.849

  • Integrated access control for up to 16 doors
  • MiFare Smart Card keypads, weather-proof external metal keypads, Internal & External LAN readers available
  • 5 onboard outputs (expandable to 37)
  • 16 onboard zones (expandable to 144 wired or wireless), partitionable to 8 areas with 990 PIN, token, keyfob and Fingerprint users

3.5" Graphic Colour WiFi Keypad |  F.01U.403.613

  • 3.5” Color graphical display with LED backlight 
  • 40bit MiFare smart card reader built-in 
  • 802.11 b/g/n Wi-Fi connectivity built-in 
  • Alpha-numeric text prompting/programming 
  • Customizable Installer banner display
  • Compatible with:

    • Solution 6000

Key Specifications


Module Connection (RS485 LAN)Max. total LAN length using multi strand 4 core (14020) security cable = 300m Max. total LAN length using 2 pair twisted shielded data cable (Belden 8723) = 1200m. See installation manual for complete wiring instructions.
CommunicationsCID, SIA, E-mail, Voice, Domestic Dialling, GMS-SMS, Connetix IP, CSV-IP
Telephone connectionRJ-12 Socket or 4-way terminal
Battery capacity (Ah)7.2 Ah
Input Voltage16-18V A.C 50-60Hz - 24VA External Power Adapter or 220-240V A.C. to 18V A.C 50-60Hz - 24VA Internal Transformer (Primary Power Source)
Operating voltage (VDC)10.2 VDC
Type of power supplyVAC; Battery
Battery TypeBosch BA 12V 7.2AH or equivalent. (Secondary Power Source).
Battery ChargerPulse by pulse charger. (Note: Charge voltage cannot be measured unless battery is fitted.)
Continuous Power1 Amp MAX (combined power drawn from Accessory Power (+12V) LAN Power (Module LAN +) and Output Power (C+) terminals must not exceed 1 Amp.
Alarm Power4 Amp (Total with primary and secondary power sources fitted)
Operating temperature (°C)0 °C – 55 °C
Operating relative humidity, non-condensing (%)5% – 85%