  • With 89mm Backset
  • Dead latched and Locked
  • Door position/Reed switch
  • Dual key override monitoring
  • Request to exit/REX
  • LED indication
  • Fail safe/fail secure configuration.
  • Multi-voltage - will work on 12-24 Vdc systems.
  • Handing - left hand and right hand doors
  • Selection of free lever or locked lever on both sides of the door
  • Key override monitoring either side of the door
  • Monitoring contacts - normally closed, normally open (for key override and request
    to exit only)

Voltage
12Vdc - 24Vdc Operating Voltage

Current
500mA (max) 80mA holding @ 12Vdc
275mA (max) 50mA holding @ 24Vdc

LED Current
When LED's are fitted, add 15mA (max) to total current draw

Monitoring

  • Dual Key override
  • Deadlatched
  • Locked
  • Door closed
  • Request to exit
  • Microswitches: 500mA (max) @ 30Vdc each circuit.
  • Reedswitch: 100mA (max) @ 30Vdc

Environment
Operational temperature range -20c to + 60c

Case / Cover
High purity Zinc alloy construction

Backset
60mm standard, 89 & 127 mm available

Latch bolts
Reversible with Stainless Steel construction.

Door Clearance
3 - 6.5 mm

Door thickness
Standard applications 32 to 50mm.

Cylinder
Standard Lockwood oval shaped cylinders.

Cabling
1.6 metre length of cable with 12 pin socket supplied with each lock.
Recommended cable: 18AWG (0.82mm²) cable runs up to 30m.

Furniture
Compatible with Lockwood series door furniture.

Standard Finishes
Satin Chrome (SC) standard.

Note: For detailed electrical specifications, refer to catalogue.

Specification Statement
The lock should be capable of operation on voltages between 12 - 24Vdc and have a current consumption not more than 80mA (holding) @12Vdc and 50mA (holding) @24Vdc.
Monitored locks must be capable of monitoring the following functions: Key override, door position / reed switch, selectable hub / Request to exit, & locking bar status.
All monitoring outputs must have the ability to be wired independently.
All settings - including: fail safe / fail secure, handing, hub selection must be field configurable.

Dimensions