Dimensions:20.8 cm x 19.5 cm x 13 cm (8 in. x 7.5 in. x 5 in.)
Material:High impact ABS plastic enclosure
Properties:With steel grid over optics area houses a removable circuit board and minor holder assembly.
Operating Temperature:-29°C to +49°C (-20°F to +120°F) For UL Certificated installations, 0°C to +49°C (+32°F to +120°F)
Radio Frequency Interference (RFI) Immunity:No alarm or setup on frequencies in the range from 26 MHz to 950 MHz at 50 V/m.
Height:3.0  m (10 ft) maximum
Location:Mounts directly to ceiling or to standard 10.2 cm (4 in.) octagonal electrical box.
Alarm:Form C reed relay rated at 3.0 W, 125 mA at 28 VDC for resistive loads and protected by a 4.7 Ω, 0.5 W resistor in the common C leg.
Tamper:Normally-closed tamper switch. Contacts rated at 28 VDC, 125 mA maximum.
Trouble:Normally-closed dry contacts rated at 28 VDC, 125 mA maximum. Open during trouble.
Current Draw:32 mA nominal at 12 VDC; up to 60 mA during walk test, stored alarm, or trouble conditions.
Voltage:9 VDC to 15 VDC