The ES2600 Series surface mounted electric strikes are high security products manufactured from solid stainless steel and designed to be used with existing and new panic bars fitted to emergency doors.

When used in conjunction with a standard access control system, these strikes convert "Exit only" doors with "Pullman type" latches into a full access controlled door, thereby allowing authorised access from the secure side.

The ES2600 series are fully monitored with both solenoid and latch/door monitoring functions & can be changed from fail safe to fail secure on site.

Key Features

  • Fail safe/fail secure changeable on site
  • High security
  • Available in 12 or 24Vdc
  • 650kg holding force
  • 1 million cycles endurance rating
  • Body depth only 27mm
  • Cast stainless steel body
  • Low current consumption - max 175Ma @ 12Vdc
  • Continuously rated solenoid
  • Installation template
  • TRICARE® 5 Year Warranty

Applications

  • For use with panic bars
  • Surface mount
  • Egress doors
  • Fire rated door sets
  • Open out door sets
  • Suitable for use with all access control systems

Standards and Compliance

  • Approved to UL1034 (highest level)
  • CE Approved
  • C-Tick Certified

Voltage
12 or 24Vdc

Current
175mA @ 12Vdc - 88mA @ 24Vdc

Solenoids
Solenoids rated for continuous use.

Monitoring
Solenoid Monitor - 1 amp NO/NC microswitch
Door / Latch Monitor - 1 amp NO/NC microswitch

Holding Force
650kg Static Strength Rating

Endurance
Cycle tested to 1,000,000 operations

Additional
Anti friction roller (patented)
Suits panic bars with 15 to 20mm Pullman latch projection

Environment
Operational temperature range - 20C to +60C

Body
Solid Stainless Steel Construction

Keeper
Stainless Steel

Latch
Suitable for 15-20mm pullman latch

Specification Statement
The strike should be constructed of solid stainless steel, have a minimum holding force of 650kg and have an endurance rating of 1 million cycles. Maximum penetration into the door frame should not exceed 12mm. The one strike must be changeable from fail safe to fail secure on site where required. The strike should not consume current greater than 175mA at 12Vdc and have a solenoid rated for continuous use. Certifications must include CE and C-Tick.