Padde Electric Strike 12VDC PTL Surface Rim Mount Weather Resistant

Voltage
12Vdc & 24Vdc

Current
250 mA @ 12Vdc - 125mA @ 24Vdc

Solenoid
Solenoids rated for continuous use.

Monitoring
None

Holding Force
680kg Static Strength Rating

Endurance
Cycle tested to 1,000,000 operations

Environment
Operational temperature range - 20Β°C to +60Β°C
Weather resistant construction available (IP56)

Body
Solid Stainless Steel Construction

Keeper
Stainless Steel

Specification Statement
The electric strike must be suitable for surface mount applications for use with rim or surface mount door locks. Where Power To Lock and Power To Open functions may be required in the same building, an individual strike is interchangeable from either "Power to Lock" or "Power to Open" on site.

The electric strike should not consume current greater than 243mA @ 12Vdc or 187mA @ 24Vdc. Certifications must include CE and C-Tick.

The strike should be tested to 1 million operations and have a minimum holding force not less than 680kg.

_________________________________________________________

Dimensions